Área Usuarios
inicio
Vídeos instalación Thermochip

Installation

Installation methods

1.- The three main principles

The Thermochip panels are normally placed on metal or wooden structures. These three basic principles must be observed for proper setup:

1.- Placement staggered, alternating cross joints between panels.

2.- The panels shall be placed so that their greater sides are perpendicular to the supports, the panel's lesser sides resting on them. A false tongue, housed along the panel shall serve as a joint among the panels.



It's easy installation, versatility of use, and the safety and duration of its useful life represent a set of notably significant economic advantages.

[up]

2.- Distribution of supports

The distance between supports is based on the panel's thickness, the roof's normal load and the foreseen overloads due to the influence of atmospheric agents. Thus, once the panel thickness has been measured according to the required level of thermal insulation, the gap shall be conditioned by the limit of the arrow due to the permanent load and overloads of use, wind and snow.

By way of information, the loads admitted by different panel types are admitted according to the number of supports for regular arrow values.

[up]

3.- Panel fastening

The distance between supports is based on the panel's thickness, the roof's normal load and the foreseen overloads due to the influence of atmospheric agents. Thus, once the panel thickness has been measured according to the required level of thermal insulation, the gap shall be conditioned by the limit of the arrow due to the permanent load and overloads of use, wind and snow.

[up]

4.- Joint between panels

Once the panels have been fastened to the bearing structure, it is a good idea to then seal the joints and ensure that the roof's watertightness against possible water leaks due to possible flaws in the covering or the action of wind, birds, etc. This sealing may be done with liquid rubber, self-adhesive waterproofing bands, silicone, polyurethane putty, bituminous sheets, etc. Waterproofing of joints is especially advisable for joints produced by the confluence of different roof gables (ridgepole, ceiling, wall, break, etc.)

The joint between Thermochip panels that display sheets of plaster on their inner face, shall be also treated with plastic with paste for joints before its final finish.

[up]

5.- Placement of finishing materials

SLATE
Placement of slate must be done on a board nailed to the panels.

TILE
Placement of flat tiles will need a board previously fastened to the panels. In the case of a curved tile, it is necessary to place some auxiliary elements that ensure the mortar's adherence to the panel (chicken wire, mesh, "under tile", etc.)

METAL SHEETING
Given its superficial uniformity and perfect flatness, the roofs built with Thermochip sandwich panel meet all suitable conditions with metal sheeting.

In this case, fastening of panels to the bearing structure must be done with countersunk head sheet metal screws In any event, .it will be a good idea for there to be a separating barrier between the metal sheets and the panel in order to avoid possible condensation.

BITUMINOUS SHEETS
Just like in the previous case, sandwich panels constitute the ideal support for covering with bituminous sheets or with any other material used in building watertight roofs.

[up]

6.- Onsite storage

Thermochip panels are supplied palletized and protected with a plastic cover. Pallets may be stacked provided the support base is properly leveled.

It is recommended not to remove the protective cover or unwrap the pallet until the panel is installed.


[up]